IBM System Storage N7000 series

IBM System Storage N7000 series

More details

 

Specifications
   N7950T
Machine type model 2867-E22
Gateway machine type model 2867-E22 (with Fibre Channel 9551)
Controller configuration Dual (active/active)
Processors speed and type 2.93 GHz Intel 6-core
Number of processors 24
Random access memory 192 GB1
Nonvolatile memory 8 GB
Integrated I/O ports
Fibre Channel ports/speed 8 (8-Gbps)
SAS ports/speed (requires FC1080) 0-24 (6 Gbps)
Ethernet ports/speed 8 (10-Gbps), 4 (1 Gbps)
Storage scalability
Maximum number of Fibre Channel loops 14
Maximum number of SAS stacks 10
Maximum raw capacity 4,320 TB
Maximum number of disk drives 1,440
Maximum volume size 100 TB
Maximum size of volumes/LUNs 4096
Maximum number of SAN Hosts Up to 512 hosts per HA pair

Up to 24 directly connected servers per HA pair
Maximum number of storage enclosures 84
Disk expansion units supported EXN4000 - Fibre Channel (FC) Disk Storage Expansion Unit: 4-Gbps FC: 300 GB, 450 GB, 600 GB (15k RPM)

EXN3500 - SAS Disk Storage (SFF) Expansion Unit: SAS: 450 GB, 600 GB (10k RPM)

EXN3000 - SAS Disk Storage Expansion Unit: SAS: 300 GB, 450 GB, 600 GB (15k RPM); SATA: 1 TB, 2 TB, 3 TB (7.2k RPM), 100 GB SSD

EXN1000 - SATA Disk Storage Expansion Unit: SATA: 1 TB, 2 TB (7.2k RPM)
I/O scalability
PCI-Express (PCI-e) expansion slots 24
PCI-x expansion slots 6
Maximum number of Fibre Channel ports 128
Maximum number of Ethernet ports 100
Maximum number of SAS ports 72
Maximum number of adapters supported per system (below - not to exceed maximum number of optional adapters)
1012 - Dual-Port GbE NIC (fibre) 24
1014 - Dual-Port 4-Gbps Fibre Channel HBA Disk 24
1015 - Dual-Port 4-Gbps Fibre Channel HBA Tape 16
1028 - Quad Port GbE (copper) 12
1029 - Quad-Port 4-Gbps Fibre Channel HBA - Disk 24
1030 - Quad-Port 4-Gbps Fibre Channel Target 12
1036 - PCIe 2 port 8 Gb Fibre Channel Target HBA 24
1061 - Quad-port 3 Gbps SAS adapter for Disk Attachment** 12
1063 - Dual-port FCoE adapter (optical) 24
1064 - Dual-port FCoE adapter (cooper) 24
1066 - MetroCluster VI Fibre Channel HBA 8Gb 2
1067 - SnapMirror over Fibre Channel HBA 8Gb 4
1071 - Flash Cache II 512Gb 32
1072 - Flash Cache II 1Tb 16
1078 - Dual-Port 10 GbE NIC, SFP+ 16
1079 - Quad-Port 8 Gb Fibre Channel HBA 6
1080 - Quad-Port 6 Gb SAS HBA 6
2013 - SFP+ 10 GbE - Embedded NIC 8
2014 - SFP+ Optical Module for 1078 32
Warranty 3 years for hardware and licensed software, CRU and Onsite service, Next Business Day 9×5, service upgrades available

**For use with the EXN3000/3500 and QSFP-QSFP cabling

1 192 GB of physical memory; actual memory allocated depends on the Data ONTAP release in use

Environmental specifications
   N7950T
Machine type model 2867-E22
Gateway machine type model 2867-E22 (with Fibre Channel 9551)
AC power/current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240 V only) 100 to 120 V ac, 6.9 A (typical), 9.6 A (maximum) @ 100 V ac

200 to 240 V ac, 3.5 A (typical), 4.7 A (maximum) @ 200 V ac
Thermal rating 6486 BTU/hr (max), 4540 BTU/hr (typical)
Weight (maximum) 260.2 lbs (118 kg)
Height 20.64 in. (52.42 cm), fits into 12U space
Width 19 in. IEC rack-compliant (17.6 in., 44.6 cm)
Depth 24 in. (61 cm), 29 in. (73.66 cm) with cable management bracket
Operating temperature, altitude, and relative humidity 10°C to 40°C (50°F to 104°F); at ≤ 3,050m (at ≤ 10,000) elevation; 20% to 80% relative humidity, noncondensing (28°C wet bulb temperature)
Nonoperating temperature and relative humidity −40°C to 70°C (−40°F to 158°F); 10% to 95% relative humidity, noncondensing, in original container
Operating acoustic noise ≤ 61 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level)
Minimum cabinet clearances 15.2 cm (6 in.) in front, 30.5 cm (12 in.) in rear
Minimum service clearances 25 in. (63.5 cm) from front of cabinet; 40 in. (102 cm) from rear of cabinet
Maximum altitude 2133 m (7,000 ft.)

 

Regulations
Filer safety EN 60950-1:2006/A11:2009, CE, NRTL (CSA 60950-1-07, UL 60950-1 Second Edition), CB (all national deviations), EN 60825-1:2007, IRAM, GOST-R
Disk shelf safety UL/C-UL; CE
Emissions FCC Class A, EN 55022:2006 +A1:2007, EN 61000-3-2:2006, EN 61000-3-3:1995 +A1:2001 +A2:2005, CE, BSMI, AS/NZ CISPR 22:2006, VCCI
Immunity EN 55024:1998 +A1:2001 +A2:2003

 

Storage expansion unit disk drive support
EXN4000 - 4-Gbps Fibre Channel Disk Storage Expansion Unit (MTM 2863-004) FC: 300 GB, 450 GB, 600 GB (15k RPM)
EXN3500 – SAS Small Form Factor (SFF) Disk Storage Expansion Unit (MTM 2857-006) SAS SFF: 450 GB, 600 GB (10k RPM)
EXN3000 - SAS Disk Storage Expansion Unit (MTM 2857-003) SAS: 300 GB, 450 GB, 600 GB (15k RPM)

SATA: 1 TB, 2 TB, 3 TB (7.2k RPM); 100 GB SSD
EXN1000 SATA Disk Storage Expansion Unit (MTM 2861-001) SATA: 1 TB, 2 TB (7.2k RPM)
Storage expansion unit specifications
Disk storage expansion units supported EXN4000: 4-Gbps Fibre Channel Disk Storage Expansion Unit (MTM 2863-004) with 14 low-profile slots for fibre channel disk drives

EXN3500: SAS Small Form Factor (SFF) Disk Storage Expansion Unit (MTM 2857-006) with 24 SFF slots for SAS SFF disk drives

EXN3000: SAS Disk Storage Expansion Unit (MTM 2857-003) with 24 slots for SAS disk drives

EXN1000: SATA Disk storage expansion unit (MTM 2861-001) with 14 low-profile slots for SATA disk drives

Legacy Support for Expansion Units
Disk drive storage shelf interface PCI-e-based Fibre Channel-Arbitrated Loop (FC-AL) or Serial attached SCSI (SAS)
Environmental specifications
Power supply/cooling fans EXN3000: Dual (SATA) or Quad (SAS) redundant, hot-pluggable, integrated power supply/fan assemblies (220 V/110 V)

EXN1000, EXN3500, EXN4000: Dual, redundant, hot-pluggable, integrated power supply/fan assemblies (220 V/110 V)
AC power/ maximum current 100 to 120 V ac/4.4 A; 200 to 240 V ac/2.3 A 100 to 120 V ac/7 A; 200 to 240 V ac/3.5 A; 50/60 Hz
Operating temperature maximum range 10°C to 40°C (50°F to 104°F)
Recommended operating temperature range 20°C to 25°C (68°F to 77°F)
Operating relative humidity range 10% to 95% relative humidity, noncondensing 10% to 95%
Recommended operating relative humidity range 40% to 55% noncondensing
Nonoperating temperature range −40°C to 65°C (−40°F to 149°F)
Nonoperating relative humidity range 10% to 95% relative humidity, noncondensing
Thermal rating 1,215 Btu/hr (fully loaded disk storage expansion unit)
Operating acoustic noise 56.4 dBA @ 1m at 23°C, 5.64 bels @ 23°C
Dimensions (height/width/depth) EXN4000 and EXN1000

3U EIA (5.25 in., 13.3 cm)/19 in. IEC rack-compliant (17.6 in., 44.7 cm)/20 in. (50.8 cm)

EXN3500

2U EIA (3.4 in., 8.5 cm)/19 in. IEC rack-compliant (17.6 in., 44.7 cm)/20 in. (50.8 cm)

EXN3000

4U EIA (6.9 in., 17.49 cm)/19 in. IEC rack-compliant (17.7 in., 44.87 cm)/25.7 in. (65.35 cm)
Weight EXN4000 - 35.8 kg (78.8 lbs) fully loaded with disk drives, 23 kg (50.6 lbs) empty

EXN3500 - 49 lbs (22.2 kg) fully loaded with disk drives, 34.6 lbs (15.7 kb) empty

EXN3000 - 110 lbs (49.9 kg) fully loaded with disk drives, 53.7 lbs (24.4 kb) empty

EXN1000 - 35 kg (77 lbs) fully loaded with disk drives, 23 kg (50.6 lbs) empty
Regulations
Disk shelf safety UL/C-UL; CE
Emissions FCC Class A, EN 55022:1998, EN 61000-3-2, EN 61000-3-3, CE, BSMI, AS/NZ 3548, VCCI
Immunity EN 55024:1998

 

Operating system Data ONTAP™ 7.2.5 or later
Operating system support Windows 2000, Windows Server 2003, Windows Server 2008, Windows XP, Sun Solaris, IBM AIX, HP-UX, Macintosh OS, ESX. Linux, VMware.
Standard software features Integrated automatic RAID manager, including RAID-DP, Snapshot, Fast Boot, Telnet, email alerts, NIS, DNS, SNMP, SecureAdmin, FlexVol, FlexShare, SSH, Maintenance Center, Network Data Management Protocol (NDMP)
Network protocol support NFS V2/V3/V4 over UDP or TCP, PCNFSD V1/V2 for (PC) NFS client authentication, Microsoft CIFS, VLD, FTP, HTTP 1.0, HTTP 1.1 Virtual Hosts
SAN protocol support Fibre Channel Protocol (FCP), FCoE for SCSI (2 Gb and 4 Gb); fabric-attached and direct-attached; iSCSI
Optional licensed functions NFS, CIFS, HTTP, Fibre Channel Protocol (FCP), iSCSI Protocol, FCoE, FlexCache, FlexClone , FlexScale, MultiStore , Clustered Failover (CFO), SnapMirror , SnapRestore , Single Mailbox Recovery for Exchange, SnapManager for Exchange, SnapManager for SQL Server, SnapManager for Oracle, SnapManager for SAP , SnapManager for Microsoft Office SharePoint (SMSP), SnapManager for Virtual Infrastructure, SnapManager for Hyper-V, SnapVault, SnapMover, SyncMirror, MetroCluster, NearStore, SnapValidator, SnapDrive for Windows, SnapDrive for UNIX, SnapDrive for AIX, SnapDrive for HP-UX, SnapDrive for Linux, AIX multipathing, Operations Manager, Disk Sanitization, Deduplication, Protection Manager, Provisioning Manager
Hardware features Full-duplex 10/100/1000Base-T Ethernet onboard console, diagnostic LED/LCD, Remote Management Card standard, redundant hot-plug cooling fans, redundant hot-plug power supplies, Compact Flash, 19 in. rack-mount enclosure, optional 220 V 42U 19 in. system cabinet
Maximum RAID group sizes RAID 6 (RAID-DP) Fibre Channel - 28 (26 data disks plus 2 parity disks), SATA - 16 (14 data disks plus 2 parity disks)

RAID 4 Fibre Channel - 14 (13 data disks plus 1 parity disk), SATA - 7 (6 data disks plus 1 parity disk)

RAID 6 + RAID 1 or RAID 4 + RAID 1 (SyncMirror)

Maximum capacity is derived based on the type, size, and number of the drives. Maximum capacity and volume size are calculated using Base10 arithmetic (i.e., 1 TB = 1,000,000,000,000 bytes).